Vacuum tube quenching furnace
model:PT-T1700

Vacuum tube quenching furnace

    Application:  It is very suitable for the laboratory study of phase change and microstructure properties of materials.
Contact us for customize send-email: info@lab-furnace.com
Zhengzhou Protech Zhengzhou Protech
Detailed Parameters Of The Product

Product overview:
    PT-T1700 vacuum tube quenching furnace uses silicon molybdenum rods as heating elements, and is equipped with a corundum tube with a diameter of 80mm and a liquid sealed container for sample quenching. The device can quickly drop samples from high temperature environments (up to 1700 degrees) into ice water or oil in liquid containers during experiments, which is very suitable for laboratory research on phase change and microstructure properties of materials.
zkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

technical parameter:zkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

Furnace structurezkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

(1) Double-layer shell structure, and an air cooling system is installed to make the surface temperature of the shell less than 55 degreeszkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

(2) 1800 type high-purity alumina fiber is used as the furnace insulation material, and the entire insulation layer is made of all-fiber materials.zkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

(3) The instrument contains a corundum furnace tube and a set of stainless steel sealing flanges (a stainless steel needle valve and a mechanical pressure gauge have been installed on it).zkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

(4) The sealed liquid container is connected to an 80mm corundum tube through a gate valve, so that the sample falls into the liquid container without contamination.zkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

powerzkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

Up to 7KWzkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

Input voltagezkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

Single phase AC220V 50HzzkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

Long-term working temperaturezkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

800-1600 ℃zkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

Maximum working temperaturezkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

1700℃ <1 hourzkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

Maximum heatingzkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

Cooling ratezkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

The temperature rise and fall rate below 1200°C is 5°C/min; the temperature rise and fall rate above 1200°C is 10°C/minzkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

Length of heating zonezkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

300 mmzkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

Length of constant temperature zonezkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

150 mm temperature accuracy: +/- 5℃zkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

Heating elementzkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

6 1800 U-shaped silicon molybdenum rodszkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

ThermocouplezkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

Type B double platinum rhodium thermocouplezkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

Monitoring thermocouplezkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

Type B double platinum and rhodium thermocouple, the upper flange has an armored thermocouple hole, and the movable thermocouple position can monitor the temperature in the tubezkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

ChillerzkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

Model: CW5200zkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

Power supply: 220v 50hz 0.52KWzkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

Cooling capacity: 1281Kcal/hzkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

Water tank volume: 6LzkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

Maximum lift: 10 MzkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

Water inlet and outlet: copper nozzle with 10mm outer diameterzkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

Temperature ControllerzkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

1. Adopt PID method to adjust the temperature and set 50 steps of temperature rising and falling programzkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

2. Temperature control accuracy +/- 1 ℃zkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

/3 33, RS485 communication interface, PC temperature control software and interface module, temperature control program and temperature curvezkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

Line into the computer;zkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

4. With over-temperature and broken couple protection, the heating circuit of the electric furnace is automatically cut off when the temperature is over or broken, allowing unattended operation (when the temperature of the electric furnace exceeds 1720 degrees or the thermocouple is blown, the AC relay on the main circuit will be automatically disconnected , The main circuit is disconnected, the ON light on the panel goes out, and the OFF light is on, limited protection of the electric furnace);zkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

5. With power-off protection function, that is, when the furnace is powered on after the power is turned off, the program does not start from the initial temperature rise, but the furnace temperature starts to rise when the power is turned off;zkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

6. The instrument has the function of temperature self-tuning;zkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

Furnace tubezkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

Material: Corundum tube OD: 80 mm; ID: 70mm; length 1000 mmzkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

The instrument must be plugged before use to prevent heat radiationzkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

Vacuum sealed flanges and valveszkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

1. A stainless steel sealing flange, hook device, ejection port and armored thermocouple pair interface are installed on the top of the furnace body;zkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

2. A plug-in valve and a mechanical pressure gauge are installed at the bottom of the furnace body;zkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

3. There is an air inlet on the bottom sealing flange, and an argon 6-60ml/min float flowmeterzkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

Customized partzkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

A 34mm round hole is reserved at the center of the upper flange for the ejection device;zkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

The symmetrical parts on both sides of the upper flange are equipped with hook devices for hanging the crucible (50*50mm), the hanging wire is molybdenum wire, and the hook device is electrically controlled, which can be controlled by PLC touch screen (provided by a third party) through the communication port;zkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

The armored structure is left on the upper flange for installing thermocouples to monitor the temperature in the tube;zkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

Quenching vesselzkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

 zkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

1. A stainless steel box for holding quenching liquid is fixed at the bottom of the furnace tube;zkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

2. A large manual flapper valve is installed between the bottom of the furnace tube and the liquid box;zkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

3. A sample hanging device that can withstand a maximum of 1500g is installed on the top of the flange;zkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

4. Push down the hanging device to release the sample into the quenching liquid box;zkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

5. Before releasing the sample, 5PSI of argon must be flushed and the manual insert at the bottom of the furnace tube must be opened.zkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

Plate valvezkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

triggerzkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

Phase shift trigger (with soft start and current limit function);zkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

Current limiting function: no matter how you adjust the heating time, the secondary current of the electric furnace after passing through the transformer is limited to less than 160A, which protects the equipment limitedly, no matter how you operate it, it will not burn the equipment;zkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

Soft start function: The current will increase slowly when starting up, and the impact on the heating element is small, which is beneficial to the extension of the life of the heating element;zkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

When the current exceeds 1.5 times of the set current, the trigger will automatically turn off to protect the circuit;zkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

The standardzkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
configuration
zkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac

1 set of furnace body, 1 corundum tube (φ80*1000mm), 1 pair of sealing flanges, 2 type B thermocouples, 5 corundum crucibles (φ50*50mm), molybdenum wire 5 meters, 1 water cooler, stainless steel box 1 (400*400*200mm), 4 pipe plugs, 8 flange seals, 1 pair of high temperature gloves, 1 crucible hook, 1 manual, 1 certificatezkVMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac